Home Up Products Saving Energy Glossary Contents About / Contact

Fronius 10.0-1UNI, 11.4-1UNI , 11.4-3Delta & 12.0-3WYE Inverters

Canadian C UL approved grid tie inverters

Fronius IG Plus

10.0-1UNI

11.4-1UNI

11.4-3Delta

12.0-3WYE277

             Input

 

Recommended PV-Power (Wp)

8500-11500

9700-13100

9700-13100

10200-13800

MPPT-Voltage range

230 - 500 V

Max. Input voltage range

600 V (at 1000 W/m 14F (-10C) in open circuit operation)

Nominal Input Current

27.6 A

31.4 A

31.4 A

33.1 A

Max. usable Input Current

46.7 A

53.3 A

53.3 A

56.1 A

Admissible conductor size (DC)

No. 14-6 AWG

             Output

 

Nominal output power (PAC nom)

9995 W

11400 W

11400 W

12000 W

Max. cont. output power
104F (40C) 208V/ 240V/ 277V

9995 W

11400 W

11400 W

12000 W

Nominal AC output voltage

208 V / 240 V / 277 V

208 V / 240 V

277 V

Operating AC voltage range
208 V
240 V
277 V

183 - 229 V (-12 / +10 %)
211 - 264 V (-12 / +10 %)
244 - 305 V (-12 / +10 %)

Nominal output current
208 V
240 V
277 V

48.1 A
41.7 A
36.2 A

54.8 A
47.5 A
41.2 A

31.6 A
27.4 A
n.a.

n.a.
n.a.
14.4 A

Max. output current
208 V
240 V
277 V

54.6 A
47.4 A
40.9 A

55.5 A
54.0 A
46.7 A

32.0 A
31.2 A
n.a.

n.a.
n.a.
16.4 A

Admissible conductor size (AC)

No. 14 - 4 AWG

Max. continuous utility back feed current

0 A

Nominal frequency

60 Hz

Operating frequency range

59.3 - 60.5 Hz

Total harmonic distortion

< 3 %

Power factor

1

     General data

 

Max. Efficiency

96.20%

CEC Efficiency
208 V
240 V
277 V


95.0 %
95.5 %
96.0 %


95.5 %
96.0 %
96.0 %


95.5 %
96.0 %
n.a.


n.a.
n.a.
96.0 %

Consumption in standby (night)

< 1 W

Consumption during operation

22 W

Cooling

Controlled forced ventilation, variable fan speed

Enclosure Type

NEMA 3R

Unit Dimensions (W x H x D)

17.1 x 48.1 x 9.6. in.

Inverter Weight

82 lbs. (37 kg)

Wiring Compartment Weight

26 lbs. (12 kg)

Admissible ambient operating temperature

-4 through 122F
(-20 through + 50C)

Compliance

UL 1741-2005, IEEE1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC Part 15 A&B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2001)

  Safety equipment

       

Ground fault protection

Internal GFDI (Ground Fault Detector/Interrupter); in accordance with UL 1741-2005 and NEC Art. 690

DC reverse polarity protection

Internal diode

Islanding protection

Internal; in accordance with UL 1741-2005, IEEE 1547-2003 and NEC

Over temperature

Output power derating / active cooling

 

Home Up Products Saving Energy Glossary Contents About / Contact

 

Contact Us: Telephone:  toll free at 1-888-810-4709 Parry Sound,Northern Ontario,Muskoka and Georgian Bay
Send mail  Linda  with questions or comments about our product or web site.

Ontario,Canada Copyright 2017, STRATEnerGY Inc.    All Rights Reserved Caribbean and US
Last modified: November 13, 2018