Home Up Products Saving Energy Glossary Contents About / Contact

Xantrex Grid Tie

Chart of Available Xantrex GT Series Inverters

Models

GT2.5-NA-DS-240

GT3.0-NA-DS-240

GT3.3-NA-DS-240

GT3.3-NA-DS-208

GT3.8-NA-DS-240

Maximum AC power output

2500 W

3000 W

3300 W

3300 W

3800 W

AC output voltage (nominal)

240 VAC

240 VAC

240 VAC

208 VAC

240 VAC

AC output voltage range

211 - 264 VAC

211 - 264 VAC

211 - 264 VAC

183 - 228 VAC

211 - 264 VAC

AC frequency (nominal)

60 Hz

60 Hz

60 Hz

60 Hz

60 Hz

AC frequency range

59.3 - 60.5 Hz

59.3 - 60.5 Hz

59.3 - 60.5 Hz

59.3 - 60.5 Hz

59.3 - 60.5 Hz

Maximum continuous output current

11.8 A

14.2 A

15.6 A

18 A

16 A

Current THD

< 3%

< 5%

< 3%

< 3%

< 3%

Power factor

> 0.9

> 0.9

> 0.9

> 0.9

> 0.9

DC input voltage range

195 - 600 VDC

195 - 600 VDC

195 - 600 VDC

195 - 600 VDC

195 - 600 VDC

Peak power tracking voltage range

195 - 550 VDC

195 - 550 VDC

195 - 550 VDC

195 - 550 VDC

195 - 550 VDC

Peak inverter efficiency

94.8%

94.6%

95.3%

94.7%

95.7%

CEC efficiency

94.0%

94.5%

94.5%

94.0%

95.0%

Night time power consumption

1 W

1 W

1 W

1 W

1 W

Output overcurrent protection

15 A

20 A

20 A

25 A

20 A

Home Up Products Saving Energy Glossary Contents About / Contact

 

Contact Us: Telephone:  toll free at 1-888-810-4709 Parry Sound,Northern Ontario,Muskoka and Georgian Bay
Send mail  Linda  with questions or comments about our product or web site.

Ontario,Canada Copyright 2017, STRATEnerGY Inc.    All Rights Reserved Caribbean and US
Last modified: November 13, 2018