Home Up Products Saving Energy Glossary Contents About / Contact

 Sundanzer System Sizing

Step 1

Determine Watt hours / day Energy Use

Step 2

Determine System Size

 

SunDanzer Model

Sun  hr.

3

4

5

6

 

Ambient

5.8 cu ft

DCR165

8 cu ft

DCR225

5.8 cu ft

DCF165

8 cu ft

DCR225

Energy

Use

Watts

PV

Watts

PV

Watts

PV

Watts

PV

Battery Size

Temp oF/C

Refrigerator 38oF / 3 oC

Freezer 10 oF / 12 oC

 

 

 

 

 

Amp Hrs

@ 12/24 V

70 / 21

117

135

407

541

100

63

48

38

32

74 / 37

72 / 22

124

145

422

559

120

76

57

46

38

89 / 45

74 / 23

133

157

439

578

140

89

67

53

44

104 / 52

76 / 24

143

169

459

600

160

102

76

61

51

119 / 60

78 / 26

155

184

480

623

180

114

86

69

57

133 / 67

80 / 27

168

199

505

647

200

127

95

76

63

148 / 74

82 / 28

182

216

531

674

220

140

105

84

70

163 / 82

84 / 29

198

234

560

702

240

152

114

91

76

178 / 89

86 / 30

215

253

591

732

260

165

124

99

83

193 / 97

88 / 31

233

274

625

764

280

178

133

107

89

207 / 104

90 / 32

253

296

661

797

300

190

143

114

95

222 / 111

92 / 33

274

320

699

833

350

222

167

133

111

259 / 130

94 / 34

296

344

739

869

400

254

190

152

127

296 / 148

96 / 36

320

370

782

908

450

286

214

171

143

333 / 167

98 / 37

345

398

828

948

500

317

238

190

159

370 / 185

100 / 38

371

426

875

990

550

349

262

210

175

407 / 205

102 / 39

399

456

925

1034

600

381

286

229

190

444 / 222

104 / 40

428

487

977

1080

650

413

310

248

206

481 / 240

106 / 41

458

520

1032

1127

700

444

333

267

222

519 / 260

108 / 42

490

554

1089

1176

750

476

357

286

238

556 / 278

110 / 43

523

589

1148

1227

800

508

381

305

254

593 / 297

Battery Sized for 4 days (50% depth of discharge.)

The Design Ambient Temperature is the maximum average weekly temperature that the cabinet is expected to operate in. If during a warm week the daily high is 100F  and the daily low is 80F, then then design ambient is 90F.

Example: DCR165- 5.8 cu.ft. refrigerator at 84F = 198 Watt-hrs/day
                In a 5 sun-hr/day region, you need at least 76 Watts of PV
                (rated) and a 148 Amp-hr battery (12 V).

850

540

405

324

270

630 / 315

900

571

429

343

286

667 / 334

950

603

452

362

302

704 / 352

1000

635

476

381

317

741 / 371

1050

667

500

400

333

778 / 389

1100

698

524

419

349

815 / 408

1150

730

548

438

365

852 / 426

1200

762

571

457

381

889 / 445

Home Up Products Saving Energy Glossary Contents About / Contact

 

Contact Us: Telephone:  toll free at 1-888-810-4709 Parry Sound,Northern Ontario,Muskoka and Georgian Bay
Send mail  Linda  with questions or comments about our product or web site.

Ontario,Canada Copyright 2017, STRATEnerGY Inc.    All Rights Reserved Caribbean and US
Last modified: April 02, 2018