Outback MPPT technology Solar Charge controllers

 

FLEXmax 80 Specifications

FLEXmax 60 Specifications

Nominal Battery Voltages

12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)

12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)

Maximum Output Current

80 amps @ 104° F (40°C) with adjustable current limit

60 amps @ 104° F (40°C) with adjustable current limit

Maximum Solar Array STC Nameplate

12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts

12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts

NEC Recommended Solar Array STC

12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems

12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems

Nameplate

5000 Watts

3750 Watts

PV Open Circuit Voltage (VOC)

150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum

150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum

Standby Power Consumption

Less than 1 Watt typical

Less than 1 Watt typical

Power Conversion Efficiency

97.5% @ 80 Amps in a 48 VDC System - Typical

98.1% @ 60 Amps in at 48 VDC System voltage - Typical

Charging Regulation

Five Stages: Bulk, Absorption, Float, Silent and Equalization

Five Stages: Bulk, Absorption, Float, Silent and Equalization

Voltage Regulation Set points

13 to 80 VDC user adjustable with password protection

13 to 60 VDC user adjustable with password protection

Equalization Charging

Programmable Voltage setpoint and Duration - Automatic Termination when completed

Programmable Voltage setpoint and Duration - Automatic Termination when completed

Battery Temperature Compensation

Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell

Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell

Voltage Step-Down Capability

Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input

Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input

Programmable Auxilary Control Output

12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC)

12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC)

Status Display

3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total

3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total

Remote Display and Controller

Optional Mate or Mate2 and Mate3 with RS232 Serial Communications Port

Optional Mate or Mate2 Mate3 with RS232 Serial Communications Port

Network Cabling

Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)

Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)

 

 

 

Data Logging

Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production

Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production

Hydro Turbine Applications

Consult factory for approved Turbines

Consult factory for approved Turbines

Positive Ground Applications

Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications)

Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications)

Operating Temperature Range

Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C)

Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C)

Environmental Rating

Indoor Type 1

Indoor Type 1

Conduit Knockouts

One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom

One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom

Warranty

Standard 5 year / Available 10 Year

Standard 5 year / Available 10 Year

Weight - Unit

12.20 lbs (5.56 kg)

11.65 lbs (5.3 kg)

            - Shipping

15.75 lbs (7.10 kg)

14.9 lbs (6.8 kg)

Dimensions - Unit

16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) - (H x W x D)

13.5 x 5.75 x 4" (40 x 14 x 10 cm)

                   - Shipping

21" x 10.5" x 9.75" (53 x 27 x 25 cm)

18 x 11 x 8" (46 x 30 x 20 cm)

Options

Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2, Mate3

Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2, Mate3

Menu Languages

English & Spanish

English & Spanish

The FM60 and FM80 is a Maximum Power Point Tracking (MPPT) regulator, and is suitable for 12, 24 or 48 V batteries. With an output current of 60 amps, the MX60 is can work with higher voltage arrays - up to 140 VDC open circuit allowing the use of smaller gauge wire when the solar array is of a distance from the battery bank.

All of the MX60’s status information is displayed on the large built-in 3.1" (8 cm) backlit LCD screen. Monitoring your solar array’s performance is easy because of included data logging system that automatically records the last 64 days of system operation. OutBack’s network communication system allows your MX60 to communicate with the rest of your OutBack system, eliminating multiple product interaction problems and allowing remote monitoring via the OutBack MATE display up to 1000 feet / 300 meters away.

Features:

  • High Operational Efficiency
  • Multi-stage charging including equalization
  • Backlit digital display for programming and monitoring performance
  • Standard 2 year warranty
  • Can reduce wiring losses by charging a 12/24 V battery from a 48-140V PV array.
  • Built in Data Logging - 64 day power production history stored in display
  • MPPT delivers more power from a solar array (up to 25%)

 Specifications

Nominal Battery Voltages 12, 24, 32, 36, 48, 54 or 60 VDC (Single model - selectable via field programming)

Output Current 60 amps for the FM60 and 80A for the FM80 maximum with adjustable current limit for smaller systems

Maximum Solar Array Size 12 VDC systems 800 Watts / 24 VDC systems 1600 Watts / 48 VDC systems 3200 Watts

PV Open Circuit Voltage (VOC) 150 VDC absolute maximum coldest conditions / 140 VDC start-up and operating maximum

Standby Power Consumption Less than 1 Watt

Charging Regulation Five Stages: Bulk, Absorption, Float, Silent and Equalization

Voltage Regulation Set points 10 to 80 VDC user adjustable with password protection

Equalization Voltage Up to 5.0 VDC above Absorb Set point Adjustable Timer - Automatic Termination when completed

Battery Temperature Compensation Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell

Voltage Step-Down Capability Can charge a lower voltage battery from a higher voltage PV array

Power Conversion Efficiency Typical 98% at 60 amps with a 48 V battery and nominal 48 V solar array

Status Display 3.1" (8 cm) backlit LCD screen with 4 lines with 80 alphanumeric characters total

Remote Interface Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)

Data Logging Last 64 days of operation - amp hours, watt hours and time in float for each day along with total accumulated amp hours, kW hours of production

Hydro / Wind Turbine Applications Consult factory for approved turbines

Positive Ground Applications Requires two pole breakers for switching both positive and negative conductors on both solar array and battery connections (HUB-4 and HUB-10 are not recommended for use in positive ground applications) Operating Temperature Range Minimum -40° to maximum 60° C (Power capacity of the controller is derated when above 25° C)

Environmental Rating Indoor Type 1

Conduit Knockouts Two ½" and ¾" on the back; One ¾" and 1" on each side; Two ¾" and 1" on the bottom

Warranty Standard 2 year / Optional 5 year

Weight Unit 11.6 lbs (5.3 kg)

Shipping Weight 14 lbs (6.4 kg)

Dimensions (H x W x L) Unit 13.5 x 5.75 x 4" (40 x 14 x 10 cm)

Shipping 18 x 11 x 8" (46 x 30 x 20 cm)

Options Remote Temperature Sensor (RTS), HUB and MATE

For more information on power generating equipment, renewable energy, wind turbines and other off grid systems call 1-888-810-4709 or email info@stratenergy.ca

 

Home Up Home Products Glossary Contents About / Contact

 

Contact Us: Telephone:  toll free at 1-888-810-4709 Parry Sound,Northern Ontario,Muskoka and Georgian Bay
Send mail
info.stratenergy@gmail.com with questions or comments about our product or web site.

Ontario,Canada © Copyright 2022, STRATEnerGY Inc.    All Rights Reserved Caribbean and US
Last modified: January 12, 2023