Fronius 5.0-1UNI, 6.0-1UNI & 7.5-1UNI Inverters

Canadian C UL approved grid tie inverters

Fronius IG Plus

5.0-1UNI

6.0-1UNI

7.5-1UNI

Input data

 

Recommended PV-Power (Wp)

4250-5750

5100-6900

6350-8600

MPPT-Voltage range

230 - 500 V

Max. Input voltage range
(at 1000 W/m² 14°F (-10°C)
in open circuit operation)

600 V

Nominal Input Current

13.8 A

16.6 A

20.7 A

Max. usable Input Current

23.4 A

28.1 A

35.1 A

Admissible conductor size (DC)

No. 14-6 AWG

  Output data

 

Nominal output power (PAC nom) Watts

5000

6000

7500

Max. cont. output power
 104°F (40°C) 208 V / 240 V / 277 V

5000

6000

7500

Nominal AC output voltage

208 V / 240 V / 277 V

Operating AC voltage range
208 V
240 V
277 V


183 - 229 V (-12 / +10 %)
211 - 264 V (-12 / +10%)
244 - 305 V (-12 / +10 %)

Nominal output current (A)
208 V
240 V
277 V


24.0 A
20.8 A
18.1 A


28.8  A
25.0 A
21.7 A


36.1 A
31.3 A
27.1 A

Max. output current (A)
208 V
240 V
277 V


27.3 A
23.7 A
20.5 A


32.8 A
28.4 A
24.6 A


37.0 A
35.5 A
30.7 A

Admissible conductor size (AC)

No. 14 - 4 AWG

Max. continuous utility back feed current

0 A

Nominal frequency

60 Hz

Operating frequency range

59.3 - 60.5 Hz

Total harmonic distortion

< 3 %

Power factor

1

  General data

 

Max. Efficiency

96.20%

CEC Efficiency
208 V
240 V
277 V


95.5 %
95.5 %
95.0 %


95.5 %
95.0 %
95.0 %


95.0 %
95.5 %
95.0 %

Consumption in standby (night)

< 1 W

Consumption during operation

15 W

Cooling

Controlled forced ventilation, variable fan speed

Enclosure Type

NEMA 3R

Unit Dimensions (W x H x D)

17.1 x 36.4 x 9.6. in.

Inverter Weight

57 lbs. (26 kg)

Wiring Compartment Weight

26 lbs. (12 kg)

Admissible ambient operating temperature

-4 ... 122°F (-20 ... + 50°C)

Compliance

UL 1741-2005, IEEE1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC Part 15 A&B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2001)

  Safety equipment

 

Ground fault protection

Internal GFDI (Ground Fault Detector/Interrupter); in accordance with UL 1741-2005 and NEC Art. 690

DC reverse polarity protection

Internal diode

Islanding protection

Internal; in accordance with UL 1741-2005, IEEE 1547-2003 and NEC

Over temperature

Output power de-rating / active cooling

Home Up Home Products Glossary Contents About / Contact

 

Contact Us: Telephone:  toll free at 1-888-810-4709 Parry Sound,Northern Ontario,Muskoka and Georgian Bay
Send mail
info.stratenergy@gmail.com with questions or comments about our product or web site.

Ontario,Canada © Copyright 2022, STRATEnerGY Inc.    All Rights Reserved Caribbean and US
Last modified: January 12, 2023