Home Up Products Saving Energy Glossary Contents About / Contact

Fronius 5.0-1UNI, 6.0-1UNI & 7.5-1UNI Inverters

Canadian C UL approved grid tie inverters

Fronius IG Plus

5.0-1UNI

6.0-1UNI

7.5-1UNI

Input data

 

Recommended PV-Power (Wp)

4250-5750

5100-6900

6350-8600

MPPT-Voltage range

230 - 500 V

Max. Input voltage range
(at 1000 W/m 14F (-10C)
in open circuit operation)

600 V

Nominal Input Current

13.8 A

16.6 A

20.7 A

Max. usable Input Current

23.4 A

28.1 A

35.1 A

Admissible conductor size (DC)

No. 14-6 AWG

  Output data

 

Nominal output power (PAC nom) Watts

5000

6000

7500

Max. cont. output power
 104F (40C) 208 V / 240 V / 277 V

5000

6000

7500

Nominal AC output voltage

208 V / 240 V / 277 V

Operating AC voltage range
208 V
240 V
277 V


183 - 229 V (-12 / +10 %)
211 - 264 V (-12 / +10%)
244 - 305 V (-12 / +10 %)

Nominal output current (A)
208 V
240 V
277 V


24.0 A
20.8 A
18.1 A


28.8  A
25.0 A
21.7 A


36.1 A
31.3 A
27.1 A

Max. output current (A)
208 V
240 V
277 V


27.3 A
23.7 A
20.5 A


32.8 A
28.4 A
24.6 A


37.0 A
35.5 A
30.7 A

Admissible conductor size (AC)

No. 14 - 4 AWG

Max. continuous utility back feed current

0 A

Nominal frequency

60 Hz

Operating frequency range

59.3 - 60.5 Hz

Total harmonic distortion

< 3 %

Power factor

1

  General data

 

Max. Efficiency

96.20%

CEC Efficiency
208 V
240 V
277 V


95.5 %
95.5 %
95.0 %


95.5 %
95.0 %
95.0 %


95.0 %
95.5 %
95.0 %

Consumption in standby (night)

< 1 W

Consumption during operation

15 W

Cooling

Controlled forced ventilation, variable fan speed

Enclosure Type

NEMA 3R

Unit Dimensions (W x H x D)

17.1 x 36.4 x 9.6. in.

Inverter Weight

57 lbs. (26 kg)

Wiring Compartment Weight

26 lbs. (12 kg)

Admissible ambient operating temperature

-4 ... 122F (-20 ... + 50C)

Compliance

UL 1741-2005, IEEE1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC Part 15 A&B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2001)

  Safety equipment

 

Ground fault protection

Internal GFDI (Ground Fault Detector/Interrupter); in accordance with UL 1741-2005 and NEC Art. 690

DC reverse polarity protection

Internal diode

Islanding protection

Internal; in accordance with UL 1741-2005, IEEE 1547-2003 and NEC

Over temperature

Output power de-rating / active cooling

Home Up Products Saving Energy Glossary Contents About / Contact

 

Contact Us: Telephone:  toll free at 1-888-810-4709 Parry Sound,Northern Ontario,Muskoka and Georgian Bay
Send mail  Linda  with questions or comments about our product or web site.

Ontario,Canada Copyright 2017, STRATEnerGY Inc.    All Rights Reserved Caribbean and US
Last modified: November 13, 2018